■ FEATURES *NEW CONTROL METHOD・・・deside the manipulation value automatically
*High Accuracy and High Response Power
*±0.2℃・・・Temperature Control Method by LOW PRICE!!(Another company's product・・・±1.0℃)
■ SPECIFICATIONS type NCS
channel 1 ch
cooling capacity 4100W(70Hz) at 0℃
5900W(70Hz)at 10℃
7700W(70Hz)at 20℃〜
heater capacity 4KW ±5% at200V
electric power supply 3Phase  200V 50/60Hz
1Phase 100V 50/60Hz
power Within10kw
Within 30A
POWER 20.3A
0.13A
control temperature range 0℃〜80℃
control accuracy ±0.3℃ maximum at0℃ 30L/min(circulation liquide)
・・・2kw load change
environment Rt5〜35℃ below Rh75%
temp control method NACS
compressor inverter scroll 1900W
cooling method water-cooled
circulation pomp SEAL-LESS Canned-moter pump 1100W
circulation pomp ability 50L/min changed by inverter contorol
(50Hz 0.5MPa) 30(30Hz0.2MPa)〜50(30Hz0.2MPa)L/min
head 8m
tank capacity 18L
coolant amount .over35L/min at25℃
supply stress0.15〜0.50MPa
water for industry or for drink
circulation liquid fluorine inert requid GALDEN(HT-200)
Flourinert(FC-3283)
refrigerant R407C
plumbing connect form fixed temp circulation requid Rc3/4   (IN・OUT)  attached pole pulp
tank drain Rc1/2            attached pole pulp
coolant Rc3/4   (IN・OUT)   attached pole pulp
flow meter degital display
temp adjustment degital design  degital display
transfer・fixaction caster・adjuster bolt
weight below 250kg(tank is empty)
CHILLER for semi-conductor machine by water cooling